Handheld Thermal Cameras

Testo 883-2 with 42° Lens

Why choose it

Its 0.1m minimum thermal focus distance lets you work close to an inspection target, with manual focus to adjust the view.1

Focus
Manual (Tested configuration: Supplied 42×32° wide angle lens: minimum focus distance 0.1m; optional 12×9° telephoto lens: minimum 0.5m)1
Thermal resolution
76,800 pixels1
Thermal sensitivity
Less than 40 mK1

The details

Specifications

Core specifications10
Testo 883-2 with 42° Lens: core specifications
Thermal resolution76,800 pixels1
Thermal sensitivityLess than 40 mK1
Maximum measurable temperature+650 °C1
Battery runtimeAt least 5 h1
Screen size3.5 in1
Frame rate9 Hz (Tested configuration: Outside the EU; the manufacturer table specifies 27Hz inside the EU)1
Weight827 g1
Visible cameraYes1
Minimum measurable temperature-30 °C2
IP ratingIP541
More specifications5
Testo 883-2 with 42° Lens: more specifications
Accuracy: degree component2 °C (Test method: Whichever is greater: ±2°C or ±2% of the reading)1
Super-resolution enhancementYes1
Data portUSB-C, USB 2.01
Power optionsLi-ion battery1
FocusManual (Tested configuration: Supplied 42×32° wide angle lens: minimum focus distance 0.1m; optional 12×9° telephoto lens: minimum 0.5m)1
Specifications not documented (6)

Wireless, Body style, Image storage, Laser pointer, Detail overlay, Add-on lenses.

Compare the tradeoffs

Alternatives

Explore Handheld Thermal Cameras

Sources

  1. www.tester.co.uk
  2. www.testequipmentdepot.com
  3. www.bosch-professional.com
  4. www.digitalcameraworld.com
  5. www.boschtools.com
  6. ocsmedia.boschtools.com

Compare two models